dc.identifier.citationAguilar, E., Marrufo, L., Neyra, W. (2024). Enhanced chromium removal from tannery wastewater through electrocoagulation with iron electrodes: Leveraging the Box-Behnken design for optimization. Helyon. https://doi.org/10.1016/j.heliyon.2024.e24647
dc.identifier.issn2405-8440
dc.identifier.urihttps://hdl.handle.net/20.500.12724/20034
dc.description.abstractThis study is focused on reducing total chromium level in tannery wastewater through the electrocoagulation process, in order to comply with the maximum permissible limits (MPL) and to determine the effects from its main operating factors. For this purpose, a batch electrocoagulation reactor was manufactured using iron electrodes. Next, the response surface methodology was applied in the experimental design using a Box–Behnken design (BBD) with three factors: current intensity, treatment time, and level. In addition, the total chromium removal percentage was taken as a response variable. The corresponding statistical analysis revealed that the treatment time, current intensity, and level variables were significant at a confidence level of . Obtained in this study for a total chromium removal were: current intensity , time , and . Our results indicated that the electrocoagulation process effectively removes total chromium from tannery effluents up to MPL values.en_EN
dc.formatapplication/html
dc.language.isoeng
dc.publisherElsevier
dc.relation.ispartofurn:issn:2405-8440
dc.rightsinfo:eu-repo/semantics/openAccess
dc.sourceRepositorio Institucional - Ulima
dc.sourceUniversidad de Lima
dc.titleEnhanced chromium removal from tannery wastewater through electrocoagulation with iron electrodes: Leveraging the Box-Behnken design for optimization
dc.typeinfo:eu-repo/semantics/article
dc.type.otherArtículo en Scopus
dc.identifier.journalHeliyon
dc.publisher.countryNL
dc.description.peer-reviewRevisión por pares
dc.identifier.doihttps://doi.org/10.1016/j.heliyon.2024.e24647
ulima.catOI
ulima.autor.afiliacionAguilar Ascón, Edwar (Universidad de Lima, Instituto de Investigación Científica, Grupo de Investigación en Tecnologías Exponenciales, Estudios Generales)es_PE
ulima.autor.afiliacionNeyra Ascón, Walter (Universidad de Lima, Instituto de Investigación Científica)es_PE
ulima.autor.carreraAguilar Ascón, Edwar (Programa de Estudios Generales)es_PE
ulima.autor.carreraNeyra Ascón, Walter (No figura en la lista del año 2023)es_PE
dc.identifier.scopusid2-s2.0-85184761173