Mostrar el registro sencillo del ítem

dc.contributor.authorAguilar Ascón, Edwar
dc.contributor.authorMarrufo Saldaña, Liliana
dc.contributor.authorNeyra Ascón, Walter
dc.contributor.otherAguilar Ascón, Edwar
dc.contributor.otherNeyra Ascón, Walter
dc.date.accessioned2020-05-04T22:35:59Z
dc.date.available2020-05-04T22:35:59Z
dc.date.issued2019
dc.identifier.citationAguilar Ascón, E., Marrufo Saldaña, L. y Neyra Ascón, W. (2019). Reduction of total chromium levels from raw tannery wastewater via electrocoagulation using response surface methodology. Journal of Ecological Engineering, 20(11), 217-224. https://doi.org/10.12911/22998993/113191es_PE
dc.identifier.issn22998993
dc.identifier.urihttps://hdl.handle.net/20.500.12724/10826
dc.descriptionIndexado en Scopuses_PE
dc.description.abstractThis study focused on reducing total chromium levels in raw wastewater from the leather tanning industry via electrocoagulation to comply with maximum permissible limits (MPL) and to determine the effects of main process parameters. An electrocoagulation reactor was built using aluminum electrodes as an anode and cathode. Then, the response surface methodology was applied using a 3k factorial design considering three factors, namely current intensity, treatment time, and pH. The total chromium removal percentage was considered as a response variable. 99% of the total chromium found in wastewater could be removed after 14-min treatment at 2-A current intensity and pH 5.5. Similar amount of chromium was removed at pH of 8.5 and 7. Statistical analysis performed at a confidence level of p < 0.05 revealed that all three factors influenced electrocoagulation. Total chromium could be efficiently removed from raw wastewater at a current intensity of 2.9 A, a pH of 8.4, and a treatment time of 21 min, suggesting that electrocoagulation using aluminum electrodes is an efficient method for total chromium removal. Thus, this process must be considered as a solution to the problems caused by the leather tanning industry and for better compliance with the MPL established in the Peruvian environmental standards.es_PE
dc.language.isoenges_PE
dc.publisherPolish Society of Ecological Engineeringes_PE
dc.relation.ispartofurn:issn:22998993
dc.relation.urihttp://www.jeeng.net/Reduction-of-Total-Chromium-Levels-from-Raw-Tannery-Wastewater-via-Electrocoagulation,113191,0,2.html
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/*
dc.sourceRepositorio Institucional - Ulimaes_PE
dc.sourceUniversidad de Limaes_PE
dc.subjectCromoes_PE
dc.subjectElectrocoagulaciónes_PE
dc.subjectAguas residualeses_PE
dc.subjectChromiumes_PE
dc.subjectElectrocoagulationes_PE
dc.subjectSewagees_PE
dc.titleReduction of total chromium levels from raw tannery wastewater via electrocoagulation using response surface methodologyes_PE
dc.typeinfo:eu-repo/semantics/article
dc.type.otherArtículo en Scopuses_PE
ulima.areas.lineasdeinvestigacionCalidad de vida y bienestar / Saneamientoes_PE
dc.publisher.countryPLes_PE
dc.description.peer-reviewRevisión por pareses_PE
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#1.06.13
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#2.00.00
dc.identifier.doihttps://doi.org/10.12911/22998993/113191
ulima.autor.afiliacionAguilar Ascón, Edwar (Universidad de Lima, Instituto de Investigación Científica (IDIC))es_PE
ulima.autor.afiliacionNeyra Ascón, Walter (Universidad de Lima, Instituto de Investigación Científica (IDIC))es_PE
ulima.autor.carreraAguilar Ascón, Edwar (Programa de Estudios Generales)es_PE
ulima.autor.carreraNeyra Ascón, Walter (No figura en la lista del año 2019)es_PE
dc.identifier.isni0000000121541816


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess