Show simple item record

dc.contributor.authorPinares-Carrillo, Hernán Daniel
dc.contributor.authorOrtega-Checa, David
dc.contributor.authorVergel-Ramírez, Karla
dc.contributor.authorChilca Alva, Manuel Luis
dc.contributor.authorNúñez-Vergara, Manuel
dc.contributor.otherChilca Alva, Manuel Luis
dc.date.accessioned2023-03-30T15:21:30Z
dc.date.available2023-03-30T15:21:30Z
dc.date.issued2023
dc.identifier.citationPinares-Carrillo, H. D., Ortega-Checa, D., Vergel-Ramírez, K., Chilca-Alva, M. L. & Núñez-Vergara, M. (2023). Proteína C reactiva como biomarcador predictivo de fuga anastomótica en cirugía oncológica colorrectal: estudio de cohorte retrospectivo. Revista Colombiana de Cirugía, 38(2), 289-299. https://doi.org/10.30944/20117582.2269es_PE
dc.identifier.issn2011-7582
dc.identifier.urihttps://hdl.handle.net/20.500.12724/17999
dc.description.abstractIntroduction. Anastomotic leak is the most serious complication of surgical treatment of colon cancer due to its high morbidity and mortality. The obvious diagnosis manifested by the exit of intestinal content through drains or the operative wound, occurs late (between the 6th and 8th day). The objective of this work was to study the postoperative C-reactive protein values to make an early diagnosis. Methods. Observational, analytical, retrospective study of a cohort of patients undergoing colorectal surgery for neoplasia, between January 2019 and December 2021, who underwent oncological surgery with intestinal anastomosis and measured CRP blood values on 1st, 3rd and 5th post-operative days. Results. Two-hundred-twenty-five operated cases that did not present leaks were compared with 45 cases with leaks, with CRP values on the 3rd and 5th day of 148mg/l and 71mg/l in cases without leakage and CRP values of 228.24mg/l and 228.04 mg/l in cases with leakage on the 3rd and 5th day, respectively (p<0.05), CRP value of 197mg/l on the 3rd day has a sensitivity of 77%; CRP value of 120mg/l on the 5th day, has a sensitivity of 84%. Conclusions. The best result for CPR to early diagnosis of anastomotic leak was observed on the 5th day, having the value of 127 mg/l the best sensitivity, specificity and NPV, which would allow early diagnosis and timely management.en_EN
dc.formatapplication/html
dc.language.isospa
dc.publisherAsociación Colombiana de Cirugía
dc.relation.ispartofurn:issn: 2011-7582
dc.rightsinfo:eu-repo/semantics/openAccess*
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/*
dc.sourceRepositorio Institucional. Ulima
dc.sourceUniversidad de Lima
dc.subjectProteinsen_EN
dc.subjectSurgeryen_EN
dc.subjectBiological markersen_EN
dc.subjectMarcadores biológicoses_PE
dc.subjectProteínases_PE
dc.subjectCirugíaes_PE
dc.titleProteína C reactiva como biomarcador predictivo de fuga anastomótica en cirugía oncológica colorrectal: estudio de cohorte retrospectivoes_PE
dc.typeinfo:eu-repo/semantics/article
dc.type.otherArtículo en Scopuses_PE
ulima.areas.lineasdeinvestigacionCalidad de vida y bienestar / Saludes_PE
dc.identifier.journalRevista Colombiana de Cirugía
dc.publisher.countryCO
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.11.04
dc.identifier.doihttps://doi.org/10.30944/20117582.2269
ulima.cat9
ulima.autor.afiliacionUniversidad de Lima
ulima.autor.carreraAdministración
ulima.autor.carreraIngeniería Industrial
dc.identifier.isni121541816
dc.identifier.scopusid2-s2.0-85149748181


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess